Item | Specifications |
---|---|
Product Number | CX-493 |
Part Number | CX-493 |
CE marking directive compliance | EMC Directive, RoHS Directive |
Sensing range | 5 m 16.404 ft (Note) The sensing range and the sensing object of the retroreflective type sensor are specifi ed for the RF-230 reflector. The sensing range represents the actual sensing range of the sensor. |
Sensing object | 50 mm 1.969 in or more opaque or translucent object (Note) The sensing range and the sensing object of the retroreflective type sensor are specifi ed for the RF-230 reflector. The sensing range represents the actual sensing range of the sensor. (Note) Make sure to confirm detection with an actual sensor before use. |
Hysteresis | - |
Repeatability(perpendicular to sensing axis) | 0.5 mm 0.020 in or less |
Supply voltage | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
Current consumption | 10 mA or less |